Will it fit on 200 amps?

A residential load calculation tells you the real size of the service a house needs, before the meter base is set or the generator is bought. One page, signed, from a licensed contractor.

NEC 220.82  ·  Lic. 55468  ·  $100 per house
01  /  What you get

The number, and what it means.

Every load on the house added up the way the code says to, with the answer in amps and a plain line on whether the service you planned is enough.

  • 01Load calculationNEC 220.82 optional method on one page, with our licence number and signature.
  • 02Service size200 amps or bigger, decided before anyone orders the meter base.
  • 03Generator sizing, 3 optionsRun everything, run everything with load shedding, or the smallest unit that still starts the AC, so the owner can pick.
  • 04Gas vs electricGas appliances listed but not loaded, so the number is honest both ways.
Sample house  ·  2,300 sq ftVA
General lighting, 3 VA / sq ft6,900
Small appliance + laundry4,500
Range / oven4,000
Dishwasher + disposal2,100
Water heater4,500
Dryer5,000
First 10 kVA at 100%10,000
Remaining 17 kVA at 40%6,800
Heat pump + 10 kW strips, 100%10,000
Total  ·  26,800 VA / 240 V112 A
Fits on 200 A  ·  Example only, not a real job
02  /  When you need one

Before the expensive part.

01

New homes

Size the service on paper, while changing it costs nothing.

02

Generators

Buy the right kW the first time, with or without load shedding.

03

EV chargers & pools

Find out if the existing panel can take the new load or needs an upgrade.

04

Additions & shops

Check the service before the new square footage goes on it.

03  /  Pricing

One price per house.

Load calculation
$100per house

Residential, NEC 220.82

  • Signed one-page load calc
  • Service size answer
  • Generator sizing sheet
Order a load calc
With a takeoff
Free

On any house plan takeoff

  • Same load calc, included
  • Plus the full material takeoff
  • House plans from $100
See takeoffs
04  /  Questions

What we need from you.

The heated square footage, which appliances are gas and which are electric, the AC size and any heat strips, and anything extra like a pool, EV charger, shop or generator. A plan set covers most of it.

It is the code's method for a single house, and it reflects how a house actually uses power. It gives a realistic service size instead of padding the number.

Yes. The same numbers give a whole house size, a smaller size with load shedding, and an AC only range, so the owner can choose with the tradeoffs in front of them.

05  /  Order

Send the house.

Email the plans, or just the square footage and appliance list. You get the signed form back by email.